4 wiring of pio converter power line connector – IAI America ERC3 User Manual

Page 159

Advertising
background image

Chapter 3 Wiring

3.7 Wiring Method

149

3.7.4 Wiring of PIO Converter Power Line Connector

The wires of the power supply and the emergency stop circuit are to be connected to the

enclosed connector (plug). Strip the sheath of the applicable wires for 10mm and insert them to

the connector. Push a protrusion beside the cable inlet with a small slotted screwdriver to open

the inlet. After inserting a cable, remove the screwdriver from the protrusion to fix the cable.

Ɣ Power Supply Connector

Connector Name

Power Supply Connector

Cable Side

MC1.5/7-ST-3.5

Enclosed in standard

package

Controller Side

MC1.5/7-G-3.5

Pin No. Signal

Name

Contents of Signals

Applicable cable diameter

1

EMG(-) Emergency-stop input

KIV AWG20 (0.5mm

2

)

2

GND

3

CP24V Power Input (24V DC

±

10%)

KIV AWG16 (1.25mm

2

)

4

MPO

5

MPI Motor drive power supply line

KIV AWG16 (1.25mm

2

)

6

S2

7

S1

Teaching pendant

Signal of emergency stop push button KIV AWG20 (0.5mm

2

)

S1
S2
MPI
MPO
CP24V
GND
EMG(-)

When inserting wires