IAI America ERC3 User Manual

Page 216

Advertising
background image

Chapter 4 Operation

4.2 Operation in Positioner Mode

4.2.3 Operation in Positioner Mode 2 (Operation Using PIO Converter)

206

(6) Binary Output of Alarm Data Output (*ALM, PM1 to 8)

Output

PIO signal

*ALM

PM1 to 8

Common to Patterns

0 to 3

{

{

Pattern 4

(Note 1)

{

u

Pattern 5

(Note 1)

{

u

{

: Available, u: Unavailable

(Note 1) Patterns 4 and 5 do not have this function.

1) If an alarm at a level equal to or higher than the operation release level occurs, completed

position number output signals PM1 to PM8 output the alarm information in the binary code

format.

2) The PLC can read the binary code of alarm signal *ALM as the strobe signal to refer to

alarm information.

{

: ON z: OFF

*ALM ALM8

(PM8)

ALM4

(PM4)

ALM2

(PM2)

ALM1

(PM1) Binary Code

Description: Alarm code is shown in ( ).

{

z

z

z

z

Normal

z

z

z

{

z

2

Software reset during servo ON (090)

Position number error during teaching (091)

PWRT signal detected during movement (092)

PWRT signal detected before completion of home

return (093)

z

z

z

{

{

3

Move command during servo OFF (080)

Position Command in Incomplete Home Return

(082)

Absolute position move command when home return

is not yet completed (083)

Movement Command during Home Return

Operation (084)

Position No. error during movement (085)

Move command while pulse train input is effective

(086)

Command deceleration error (0A7)

z

z

{

z

z

4

Mismatched PCB (0F4)

z

z

{

z

{

5

z

z

{

{

z

6

Parameter data error (0A1)

Position data error (0A2)

Position command data error (0A3)

Unsupported motor/encoder type (0A8)

z

z

{

{

{

7

Excitement detection error (0B8)

Home return timeout (0BE)

(Note) *ALM Signal is an active low signal. It is ON when the power is applied to the controller, and

turns OFF when the signal is output.