IAI America ERC3 User Manual

Page 362

Advertising
background image

Chapter 7

Troubleshooting

7.1

Action to Be

Taken upon Occurrence of Problem

352

2) Check whether an alarm occurs on the host controller (PLC, etc.).

3) Check the voltage of the main power supply (24V DC).

4) Check the voltage of power supply for the PIO (24V DC).

5) Alarm Check

(Note1)

Check the alarm code on the teaching tool such as PC software.

6) Check the connectors for disconnection or connection error.

7) Check the cables for connection error, disconnection or pinching.

Cut off the main power of the system which ERC3 or PIO converter is installed in and

remove the cables around the measurement point (to avoid conductivity through the

surrounding circuit) before checking the conductivity.

8) Check the I/O signals.

Using the host controller (PLC, etc.) or a teaching tool such as PC software, check the

presence of inconsistency in I/O signal conditions.

9) Check the noise elimination measures (grounding, installation of surge killer, etc.).

10) Check the events leading to the occurrence of problem

(Note 1)

, as well as the operating

condition at the time of occurrence.

11) Analyze the cause.

12) Treatment

Note 1 If parameter No.111 (Selection of using calendar function) is set to “1” (use), it is

possible to know the date and time at which the alarm occurred.

Set the date and time from the teaching tool such as PC software at the first

power-on of the ERC3 and PIO converter.

The date and time data set once is retained for about 10 days if the power supply

of the PIO converter is OFF. If the setting is not conducted or the time data is lost,

it will be the time passed since 0sec when the power is turned ON. Even if the

date and time data is lost, the generated error code is retained.

Alarms subject to this function only include those in 7.4 Alarm but do not include

errors in the teaching tool such as PC software.

Request:

In troubleshooting, exclude normal portions from suspicious targets to narrow down

the causes. Check 1) to 10) described above before contacting us.

Advertising