IAI America ERC3 User Manual

Page 171

Advertising
background image

Chapter 4 Operation

4.2 Operation in Positioner Mode

4.2.1 Set of Position

Table

161

8) Positioning width [mm] ······In PIO Patterns 0 to 4 in Positioner Mode 1 (for ERC3 unit) and

Positioner Mode 2 (when PIO Converter is used), the

positioning complete signal is output when the remaining

movement amount gets into the area that is set in them when

positioning is conducted.

For pressing, actuator will first move to the position of the

coordinate set in 2) at the set velocity, acceleration, and

deceleration. It will then, performs pressing movement by the

data set here.

For the positioning width, make its width at least 4 times larger

than the minimum unit of the movement (movement amount of

1 pulse of the encoder) of the used actuator.

It is not the output range of the complete signal for the

positioning command if PIO pattern 5 of PIO converter. Despite

the specified position number, the relevant output signal LS* is

turned ON when the actuator reaches the setting range. The

operation is accomplished as if a sensor were installed to

detect the actuator. PIO pattern 5 does not correspond to the

pressing operation.

[Example for Positioner Mode 2, PIO Pattern 5 of PIO Converter]

The figure below shows the position table and the position at which each of the LS signals is

turned ON. If the actuator passes any of the positioning width in the operation by another

position number or manual operation in the servo-off state, the relevant LS signal is always

turned ON.

No.

Position

[mm]

Velocity

[mm/s]

Accele-

ration

[G]

Decele-

ration

[G]

Pressing

[%]

Thresh-

old

[%]

Positioning

width

[mm]

Zone+

[mm]

Zone-

[mm]

Acceleration/

Deceleration

mode

Incre-

mental

Transported

load

Stop

mode

0

0.00

250.00

0.20

0.20

0

0

5.00

0.00

0.00

0

0

0

0

1

70.00

250.00

0.20

0.20

0

0

10.00

0.00

0.00

0

0

0

0

2

150.00

250.00

0.20

0.20

0

0

5.00

0.00

0.00

0

0

0

0

9) Zone + [mm] ·············Set the coordinate value on the positive side at which position zone

output signal PZONE is turned ON. PZONE is set to ON in the zone

between this value and the coordinate value on the negative side set

in 10).

The feature follows the specified position number. It is valid only

when the position is specified but invalid in another position

operation.

10) Zone - [mm]··············Set the coordinate value on the negative side at which position zone

output signal PZONE is turned ON.

70mm

Home=0mm

LS2 is ON

150±5mm

LS1 is ON

70±10mm

LS0 is ON

0±5mm

150mm

Advertising