(4) Error monitor during torque limiting

No.

Name

Symbol

Unit

Input

Range

Initial

Value

59

Error monitor during torque limiting

FSTP

0 to 1

0

Selection can be made whether to enable/disable the motoring of the deviation during torque

limiting (condition of TL signal being ON).

If it is set enabled, error can be issued when the deviation exceeds the specified value while in

torque limiting.

0: Disable

1: Enable

(5) Deviation Counter Clear Input

No.

Name

Symbol

Unit

Input

Range

Initial

Value

60

Deviation Counter Clear Input

FPIO

0 to 1

0

Selection can be made whether to enable/disable the deviation counter clear signal DCLR.

0: Enable

1: Disable

(6) Torque limit command input

No.

Name

Symbol

Unit

Input

Range

Initial

Value

61

Torque limit command input

FPIO

0 to 1

0

Torque control of the motor with the value set in Parameter No.57 Torque Control Value can be

performed with PIO (TL Signal ON) from the host system. In this parameter, a choice can be

made from using (activated) TL Signal (Torque Limiting Signal) and not using (deactivated) the

signal.

If selected to be invalid, TL Signal (torque limit signal) becomes invalid.

0: Enable

1: Disable

(7) Pulse count direction

No.

Name

Symbol

Unit

Input

Range

Initial

Value

62

Pulse count direction

FPIO

0 to 1

Set

individually

You can set the direction in which the motor turns according to command pulses.

0: Forward rotation

1: Reverse rotation