Chapter 1 Specifications Check

1.2 Specifications

1.2.2 Built-in Controller

61

(2) Pulse Train Input Interface

Interface

Line Driver Input

Specification

Positioning Unit

0V

PP

/PP

NP

/NP

Equivalent to

Line Driver 26C31

ERC3 Control Power Supply

Connected to 0V line on 24V DC

Pulse Train Output

For the host positioning unit, use the line driver 26C31 or equivalent

with pulse train output specification.

Format of Pulse

Train

Refer to 4.3 [7]

Connection Cable

PIO type power and I/O cable [Refer to 3.2.3 [3]]

(3) Pulse converter : AK-04 (Please purchase separately)

Use this by connecting to the host controller pulse train output when the host controller

output pulse is open collector type.

It converts the command pulse of the open collector type to the differential type.

Item

Specifications

Input Power

Supply

24V DC ±10% (MAX. 50mA)

Input Pulse

Open collector (Collector current MAX. 12 mA)

Input Frequency 60Kpps or less

Output Pulse

Differential output equivalent to 26C31 (MAX.10mA)

Weight

10g or less (Cable connector excluded)

Accessories

37104-3122-000FL (e-CON connector) 2 Units Cover color: YW

Applicable wire AWG24

(Less than 0.2 to 0.3mm

2

, finished O.D. I1.0 to

1.2mm)

 

Caution

1) Use the pulse converter in the surrounding temperature range between 0 and 40qC.

2) The temperature increase of about 30qC occurs during operation. Accordingly, neither

install several pulse converters in close contact nor install them within a duct.

Do not install the pulse converter near other heating devices.

3) If more than one pulse converters are installed, set a pulse converter apart from another by

10mm or more.

To avoid noise, connect it within 50mm of the pulse train output terminal.