Chapter 4 Operation

4.2 Operation in Positioner Mode

4.2.3 Operation in Positioner Mode 2 (Operation Using PIO Converter)

214

 

Caution: (1) If the actuator reaches the software limit corresponding to the stroke end in the pitch

feed operation, the actuator stops at the position and positioning complete signal

PEND is turned ON.

(2) Note that, in pitch feed just after pressing operation (to be in the pressing state), the

start position is not the stop position at the completion of pressing but the

coordinate value entered in “Position” of the pressing position data. The movement

to the base point is added to the first pitch feed.

(3) If the position number for pitch feed is started (CSTR ON) during normal positioning,

the actuator moves to the position of the coordinate resulting from adding the pitch

feed distance to the target coordinate of the positioning. Repeating the start of pitch

feed several times allows the pitch feed distance to be added to the target position

by the number of repeats. Do not use the pitch feed function in such a way, because

the PLC cannot confirm the complete position.

(4) Note that, if pitch feed is started (CSTR ON) repeatedly during pause, the actuator

moves continuously by the distance based on the number of starts. In such a case,

cancel the remaining moving distance by turning reset signal RES to ON in the

pause state or take interlock so that the start signal is not turned ON during pause.

(5) At software limit (stroke end) in pitch feed, the actuator is decelerated to be stopped

and positioning complete output PEND is output.

(6) MOVE turns ON at the start of an operation and PEND turns OFF at almost the

same time. MOVE turns OFF when there is no more movement command existing.

Therefore, in the normal stop, PEND turns ON after MOVE is turned OFF, however,

when the positioning width setting is wide, PEND would turn ON even during an

operation of the actuator.

(7) Pressing is enabled by using the pitch feed function. However, do not make control

of changing to pitch feed on the way of normal positioning (before PEND turning

ON). Pressing is interrupted by using the pitch feed function as soon as start signal

CSTR is turned ON. The PLC cannot manage the position of the actuator any more.

Approach operation

Pressing operation

Current stop position

Base point of pitch feed

Movement to base point of pitch feed +

pitch feed distance

Second and following

pitch feed

= setting value

Return to base point and first pitch feed

Pressing operation

Second and following

pitch feed

= setting value

Pitch feed in reverse pressing operation

Pitch feed in same direction

as pressing operation