IAI America ERC3 User Manual

Page 316

Advertising
background image

Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

306

I/O Parameter List (Continued)

No.

C

at

eg

or

y

Name

Symbol

Unit

Input Range

Default factory

setting

For

Positioner

Mode 1

For

Positioner

Mode 2

For Pulse

Train

Mode

Relevant

sections

This section

60 B Deviation counter clear input

FPIO

0: Enabled

1: Disabled

0

{

Chapter 3

3.3.5 [5]

61 B Torque limit command input

FPIO

0: Enabled

1: Disabled

0

{

Chapter 3

3.3.5 [6]

62 B Pulse count direction

FPIO

0: Forward motor

rotation

1: Reverse motor

rotation

In accordance with

actuator

(Note1)

{

Chapter 3

3.3.5 [7]

63 B Command pulse input mode

(Pulse train mode)

CPMD

0 to 2

1 (pulse-train and

moving direction

angle)

{

Chapter 3

3.3.4 [2]

64 B Command pulse input mode polarity CPMD

0: Positive Logic

1: Negative Logic

0

{

Chapter 3

3.3.4 [2]

65 B Electronic gear numerator

CNUM

1 to 4096

2048

{

Chapter 3

3.3.4 [1]

66 B Electronic gear denominator

CDEN

1 to 4096

125

{

Chapter 3

3.3.4 [1]

67 B Compulsory stop input

FPIO

0: Enabled

1: Disabled

0

{

Chapter 3

3.3.5 [8]

71 B Feed forward gain

PLFG

0 to 100

0

{

{

{

[2] (53)

77 D Ball screw lead length

LEAD

mm

0.01 to 999.99

In accordance with

actuator

(Note1)

{

{

{

[2] (54)

83 B Absolute unit

ETYP

0: Incremental

1: Simple Absolute

Type

In accordance with

specification at

order accepted

{

[2] (55)

88 D Software limit margin

SLMA

mm

0 to 9999.99

In accordance with

actuator

(Note1)

{

{

{

[2] (56)

91 C Current limit value at stopping due

to miss-pressing

PSFC

0: Current limit value

during movement

1: Current limit value

during pressing

0

{

{

[2] (57)

110 B Stop method at servo OFF

FSTP

0: Rapid stop

1: Deceleration to

stop

0

{

{

{

[2] (58)

111 B Calendar function

FRTC

0: Does not use the

calendar timer

1: Use the calendar

timer

1

{

[2] (59)

112 B Monitoring mode

FMNT

0: Does not use

1: Monitor function 1

2: Monitor function 2

0

{

{

{

[2] (60)

113 B Monitoring period

FMNT

msec

1 to 100

1

{

{

{

[2] (61)

Note 1 The setting values vary in accordance with the specification of the actuator. At shipment, the

parameters are set in accordance with the specification.