Ii. position zone signal pzone – IAI America ERC3 User Manual

Page 180

Advertising
background image

Chapter 4 Operation

4.2 Operation in Positioner Mode

4.2.2 Operation in Positioner Mode 1

170

II. Position zone signal PZONE

No.

Position

[mm]

Velocity

[mm/s]

Accele-

ration

[G]

Decele-

ration

[G]

Pressing

[%]

Thresh-

old

[%]

Positioning

width

[mm]

Zone+

[mm]

Zone-

[mm]

Acceleration/

Deceleration

mode

Incre-

mental

Transported

load

Stop

mode

0

1

0.00

250.00

0.20

0.20

0

0

0.10

50.00

30.00

0

0

0

0

2

100.00

250.00

0.20

0.20

0

0

0.10

70.00

60.00

0

0

0

0

3

50.00

250.00

0.20

0.20

50

0

20.00

60.00

65.00

0

0

0

0

Zone ranges should be set in the position table.

While the operation corresponding to a position number is executed, the zone range set for the

position number is valid. It is kept effective also during the emergency stop unless the actuator

is operated or the memory of the origin is lost due to alarm.

III. Setting values and signal output range

The zone output range varies depending on the difference between the value set for the

positive side of the zone and that for the negative side.

1) Value set for positive side > value set for negative side: The output signal is set to ON in

the range and OFF out of the range.

2) Value set for positive side < value set for negative side: The output signal is set to OFF in

the range and ON out of the range.

[Example]

Caution: (1) Since zone signal becomes effective after the coordinate system is established

after the home return is completed, it would not be output just with the power

turned ON.

(2) The zone detection range would not turn ON unless the value exceeds that of

the minimum resolution (actuator lead length/800).

Setting of zone range

Current

Position

Zone Signal Output

Zone Signal Output

0mm

30mm

70mm

100mm

ON

ON

ON

Set Value

Zone setting + : 70mm

Zone setting - : 30mm

Set Value

Zone setting + : 30mm

Zone setting - : 70mm

Advertising