Chapter 4 Operation

4.3

O

per

at

io

n

in

P

ul

se

T

rai

n

Co

nt

ro

l M

od

e

(Ho

w

to

O

per

at

e

Pulse

Train Control

Type)

254

[8] Settings of Basic Parameters Required for Operation

It is a mandatory parameter to perform an operation.

The parameters listed in the table below may only be set if the actuator performs only

positioning operation.

Parameter No. Parameter Name

Details

65

Electronic Gear Numerator

66

Electronic Gear Denominator

This parameter determines the unit travel distance of the

actuator per command pulse train input 1 pulse.

63

Command Pulse Mode

Specifies the command pulse train input mode.

64

Command Pulse Mode Input

Polarity

Sets the type of active high/low of the specified pulse

train

(1) Electronic Gear Setting

This parameter determines the unit travel distance of the actuator per command pulse train

input 1 pulse.

User Parameter No.65/66 Electronic Gear Numerator/Denominator

Name

Symbol

Unit

Input Range

Initial Value

(For reference)

Electronic Gear

Numerator

CNUM

1 to 4096

2048

Electronic Gear

Denominator

CDEN

1 to 4096

125

Determine the movement amount and calculate value for the electronic gear setting by

following the formula below:

Linear Axis Unit Travel Distance = Min. Travel Distance Unit (1, 0.1, 0.01mm etc.) / pulse

Rotary Axis Unit Travel Distance = Min. Travel Distance Unit (1, 0.1, 0.01deg. etc.) / pulse

„

Electronic Gear Formula:

In the case of Linear Axis

Note 1 The encoder pulse of ERC3 is 800pulse/rev.

„

Formula for velocity:

The velocity of the actuator can be figured out with the following formula.

Velocity = Unit Travel Distance u Input Pulse Frequency [Hz]

Electronic Gear

Numerator (CNUM)

Electronic Gear

Denominator (CDEN)

= No. of Encoder Pulses

(Note 1)

[pulse/rev]

Actuator Lead Length [mm/rev]

u

Unit Travel Distance [mm/pulse]