(5) Pause and Operation Interruption (ST*, LS*)

Turning start signal ST* OFF allows the actuator to be paused while it is moved. To restart it,

turn the same ST* signal ON.

„

Control method

If start signal ST* is turned OFF during movement, the actuator can be paused.

Use the control method for interlock in case where an object is invaded into the moving

direction of the actuator being moved.

1) If the ST* signal is turned OFF during movement, the actuator is decelerated to a stop. The

deceleration is the value set in the position table.

2) If the ST* signal is turned ON again, the remaining movement is continued. The

acceleration is the value set in the position table.

Before operation

Positioning

complete state

Operation

Temp.

stop

Cont.

Op.

Position

complete

Velocity

Operation of actuator

Start signal

ST*

(PLCoController)

LS* not

turned ON

Position sensing output

LS*

(ControlleroPLC)

Deceleration

and stop with

Start signal for

position 1

tuirned OFF

Movement

restart with

Start signal for

position 1

tuirned ON