IAI America ERC3 User Manual

Page 194

Advertising
background image

Chapter 4 Operation

4.2 Operation in Positioner Mode

4.2.2 Operation in Positioner Mode 1

184

(7) Pause and Operation Interruption (*STP, PEND)

Input

Output

Model name

PIO signal

*STP

PEND

ERC3 Main Body Pattern 0 and 2

{

{

{

: Available, u: Unavailable

„

Control method

Pause is possible during movement. The pause signal is an input signal always set to ON. So,

it is normally used to remain ON. Use this as an interlock in such a case interference gets into

the moving direction while the actuator is operating.

1) If pause signal *STP is turned off during operation of the actuator, the actuator is

decelerated to a stop. The deceleration is defined by the value set in the position table.

2) The positioning complete signal PEND would not turn ON while in pause.

3) If pause signal *STP is returned to ON, the actuator continues the remaining movement.

The acceleration is the value set in the position table.

 

Caution: Turning *STP OFF with the actuator being in the positioning complete state

causes PEND to be turned OFF. Note that this situation may not occur

when a sequence program is created.

Before operation

Positioning complete state

Operation

Temp.

stop

Cont.

Op.

Position

complete

Pause signal *STP

(PLCoController)

Positioning completion signal

PEND

(ControlleroPLC)

Operation of actuator

PEND turned

OFF

PEND not

turned ON

Velocity

Positioning

Completion

Signal Output

1)

2)

3)

4)

5)

1)

2)

3)

4) 5)

Advertising