Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

329

(57) Current limit value at stopping due to miss-pressing (Parameter No.91)

No.

Name

Symbol

Unit

Input Range

Default factory setting

91

Current limit value at stopping

due to miss-pressing

PSFC

0: Current limiting

value at stop

1: Current limit

value during

pressing

0

This parameter defines the restricted current value at stopping due to miss-pressing.

Servo-lock is executed following this setting until the next movement command.

Parameter No.91

Description

0

Current limitation value while in operation stop (setting value in the

current limiting value at positioning stop (Parameter No.12))

1

Press-motion current-limiting value

(58) Stop method at servo OFF (Parameter No.110)

No.

Name

Symbol

Unit

Input Range

Default factory setting

110 Stop method at servo OFF

PSOF

0: Rapid stop

1: Deceleration to

stop

0

Select the stop method of when the servo is turned OFF during an operation. If 1 is selected,

the actuator decelerates with position data in execution and stops.

(59) Calendar function (Parameter No.111)

No.

Name

Symbol

Unit

Input Range

Default factory setting

111 Calendar function

FRTC

0: Unused

1: Use

1

Select use/not use of the calendar function (RTC) in PIO converter.

Set the current time with using a teaching tool when the calendar function is used.

[Refer to the instruction manual of the teaching tool for the details.]

In use of RTC, the alarm occurrence time in the alarm list is the time at which an alarm has

occurred.

If RTC is not in use, the alarm generated time in the alarm list shows the time passed since

0sec that is the time the power is supplied to the controller.

Set Value

Description

0

Unused

1

Use