Chapter 6

Adjustment of Operation

6.3 I/O Parameter

6.3.1 Positioner Mode 1, Positioner Mode 2 and Pulse

Train Control Mode

334

(72) Absolute battery retention time (Parameter No.155)

No.

Name

Symbol

Unit

Input Range

Default factory setting

155 Absolute battery retention

time

AIP

days

0: 20 days

1: 15 days

2: 10 days

3: 5 days

0

For Simple Absolute Type, establish the setting to define how long the position information of

the encoder is to be remained for after the power to the controller is turned OFF. Setting can be

done from four grades. Maximum number of the motor revolution due to external force during

the power is OFF is controlled by the set days. Establish the setting assuming the speed when

the work transporting parts, slider or rod, on the actuator is moved by external force during the

power being OFF. The position information will lose if the number of motor revolution exceeds

the set value. Consider safety margin when establishing the setting.

Motor rotation [rpm] Moved speed [mm/s] / Lead length [mm] u 60

Setting

Position information

retaining day (reference)

Motor max. rotation speed

(rpm)

0 (Initial setting)

20 days

100

1

15 days

200

2

10 days

400

3

5 days

800

(73) Torque check/Light malfunction output select (Parameter No.156)

No.

Name

Symbol

Unit

Input Range

Default factory setting

156 Torque check/Light

malfunction output select

SLAL

0: Load judge

output or torque

level status

signal output

1: Output of battery

voltage drop

warning or

message-level

alarm

0

This parameter is not used.