Chapter 4 Operation

4.2 Operation in Positioner Mode

4.2.3 Operation in Positioner Mode 2 (Operation Using PIO Converter)

209

[6] Operation with the Position No. Input = Operations of PIO Patterns 0 to 3

This is the operation method for PIO Patterns 0 to 3. This is a standard operation method when

using PIO Converter that operates by turning the start signal ON after inputting the position

number.

The control methods of positioning, pitch feed, and pressing are the same as those described

before.

(1) Positioning [Basic] (PC1 to PC**, CSTR, PM1 to PM**, PEND, MOVE)

Input

Output

PIO signal

PC1 to PC** CSTR PM1 to PM** PEND MOVE

PIO pattern 0

PC1 to 32

{

PM1 to 32

{

{

PIO pattern 1

PC1 to 32

{

PM1 to 32

{

{

PIO pattern 2

PC1 to 128

{

PM1 to 128

{

u

PIO pattern 3

PC1 to 256

{

PM1 to 256

{

u

{

: Available, u: Unavailable

(Note) Operation without home return leads the operation based on the data of the specified

position No. after automatic home return. If one or more problems are found, interlock

by home return complete signal HEND is required.

„

Sample use

No.

Position

[mm]

Velocity

[mm/s]

Accele-

ration

[G]

Decele-

ration

[G]

Pressing

[%]

Thresh-

old

[%]

Positioning

width
[mm]

Zone+

[mm]

Zone-

[mm]

Acceleration/

Deceleration

mode

Incre-

mental

Transported

load

Stop

mode

0

1

70.00

100.00

0.20

0.20

0

0

0.10

0.00

0.00

0

0

0

0

2

150.00

200.00

0.20

0.20

0

0

0.10

0.00

0.00

0

0

0

0

Positioning

Completion

Signal Output

Velocity

Positioning

Completion

Signal Output

1)

2)

3)

4)

5)

6)

7)

8)

1) 2)

5) 6)

3) 4)

7) 8)