CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Front Panel Operation

Revision 2

6–10

(CONFIG: Remote Control) Serial: Baudrate

Local M&C Bus Baud Rate:

19200 Baud (▲ ▼,ENTER)

Valid baud rates (in bps) are 2400, 4800, 9600, 19200, 38400, or 57600.

Use the ▲▼arrow keys to select the baud rate of the remote M&C bus that is connected

locally to the User PC, bps. Press ENTER.

The asynchronous character format is FIXED at 8 data bits, 1 stop bit, no parity

(8-N-1).

6.3.2.1.2 (CONFIG:) Remote Control: Ethernet

In Ethernet mode, Serial monitoring is allowed; however, Serial control is not allowed

except for use of the LRS (Local/Remote Status) and FPL (Front Panel Lockout)

commands and queries.

Ethernet Config: Gateway

Address MAC SNMP (◄ ►)

Use the

◄ ►

arrow keys to select a parameter. Press ENTER.

(CONFIG: Remote Control) Ethernet: Gateway

Ethernet IP Gateway:

192.168.001.002 (◄ ►,▲ ▼)

To edit the modem ‘M&C’ Ethernet port IP Gateway Address, use the

◄ ►

arrow keys to

select a digit, and then use the ▲▼arrow keys to change that digit. Press ENTER.

(CONFIG: Remote Control) Ethernet: Address

Ether IP Address/Range:

192.168.001.002/24(◄ ►,▲ ▼)

To edit the modem ‘M&C’ Ethernet port management and data traffic IP Address and Range,

use the

◄ ►

arrow keys to select a digit, and then use the ▲▼arrow keys to change that

digit. Press ENTER.

(CONFIG: Remote Control) Ethernet: MAC

M&C Port MAC Address:

00-06-B0-00-01-06 (ENTER)

This read-only screen displays the unit MAC Address. Press ENTER or CLEAR to exit this

menu.