5 bulk configuration commands and queries – Comtech EF Data CDM-570A User Manual

Page 275

Advertising
background image

CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Serial-based Remote Product Management

Revision 2

8–35

8.3.5

Bulk Configuration Commands and Queries

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

OGC Outdoor Unit

Global

Configuration

OGC=

50 Bytes

Command or Query – CDM/R-570AL only.

Sets or returns ODU Global Configuration of CDM/R-570AL in the form

aabcdexxxxhhhhiiiijjjjjkxxxxxxlmnnnooopppppqxxxxxx, where:

OGC=

OGC?

OGC*

OGC#

OGC?

OGC?n

OGC=aabcdfxxxhhh

hiiiijjjjjkxxxxxxlmnnn

ooopppppqxxxxxx

Where n=0 to 9

returns the OGC

portion of 1 of 10

stored configs

(see Description of

Arguments)

aa = BUC Address

b = BUC FSK comms enable

c = BUC Power Control

d = BUC 10MHz Frequency Reference enable

e = BUC Tx Output Enable

xxxx = expansion bytes

hhhh = BUC Low Alarm Limit

iiii = BUC High Alarm Limit

jjjjjk = BUC LO frequency, mix sign

xxxxxx = expansion bytes

l = LNB Power Control

m = LNB 10MHz Frequency Reference enable

nnn = LNB Low Alarm Limit

ooo = LNB High Alarm Limit

pppppq = LNB LO Frequency, mix sign

xxxxxx = expansion bytes

Any unavailable parameters will be filled with xxx.

same as BAD

same as BCE

same as BPC

same as BFR

same as BOE

same as BCL

same as BCH

same as BLO

same as LPC

same as LFR

same as LCL

same as LCH

same as LLO

Global

Configuration in

CDM-570A

Compatible Mode

(CMO=1)

MGC=

200 bytes, with

numerical entries,

fixed values, and

delimiters.

Command or Query.

Sets or returns Global Configuration of CDM570AL, in CDM-570A Compatible

Mode (CMO=1), in the form shown in Response to Query column, where:

MGC=

MGC?

MGC*

MGC#

MGC?

MGC=abcdddd.ddd

defghhhhh.hhhijkk.k

lmnoppp.ppqrrstxxx

AAAA.AAAABCDE

EEEE.EEEFGHIIIJJ

.JKLMxxxxxxNOPP

PPQRRRRRRRRR

RRRSTUVxxxxxxm

MATrrrr.rrrssss.sss

abxcedfffgggGGGx

xxxxxxxxxxxxxxxxx

xxxxxxxxxxxxxxxxx

xxxxxxxxxxxxx

(see Description of

Arguments)

a = Unit Interface Type

b = T1 Line build-out

c = Unit Framing mode

dddd.dddd = Tx Frequency

e = Tx FEC Type

f = Tx Modulation type

g = Tx FEC Rate

hhhhh.hhh = Tx Data Rate

i = Tx Spectrum Inversion

j = Tx Scrambler State

kk.k = Tx Power Level

l = Tx Clock Source

m = Tx Data Invert

n = Tx Carrier Stat

same as ITF

same as LBO

same as FRM

same as TFQ

same as TFT

same as TMD

same as TCR

same as TDR

same as TSI

same as TSC

same as TPL

same as TCK

same as TDI

same as TXO