CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Appendix N

Revision 2

N–6

N.4 CDM-570A/570AL-IP 1:1 IP Data Switching Functional Description

When the CDM-570A/570AL-IP modem is using a serial data interface (for example, RS.422 or

V.35), the paired modems are connected to a CRS-180 (or CRS-170A) 1:1 Redundancy Switch

with an adapter Y-cable. When the CDM-570A/570AL-IP is using the optional Packet Processor

as the data interface, as shown in Figure N-2, you may use a standard Ethernet Layer 2 Switch or

Hub (it is recommended that you use a Layer 2 Switch).

Figure N-2. CDM-570A/570AL-IP 1:1 IP Redundancy

Example (Router Mode Shown, Modem ‘A’ Online)

For CDM-570A/570AL-IP IP 1:1 redundancy operation, both CDM-570A/570AL-IP s are assigned

a unique M&C IP address on the same subnet (in Figure N-2, 172,18.10.21/24 and

172.18.10.22/24). A Traffic IP address on the subnet is also assigned (172.18.10.20/24).

Whichever modem is online also assumes the Traffic IP.

When there is a switchover to the backup modem, this modem now assumes the Traffic IP. It

also broadcasts a “Gratuitous ARP” that tells all local devices to now associate a new MAC