8–32

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

Tx BERT

Pattern

TBP=

1 byte

Command or Query.

Valid only in CDM-570A Compatible Mode (CMO=1).

Sets or returns Tx BERT Pattern, in the form x, where:

0=1:1

1=2047

2=2^15-1

3=2^23-1

Example: <0/TBP=1 (Tx BERT Pattern is 2047)

TBP=

TBP?

TBP#

TBP?

TBP=x

(see Description of

Arguments)

Rx BERT

Pattern

RBP=

1 byte

Command or Query.

Valid only in CDM-570A Compatible Mode (CMO=1).

Sets or returns Rx BERT Pattern, in the form x, where:

0=1:1

1=2047

2=2^15-1

3=2^23-1

Example: <0/RBP=1 (Rx BERT Pattern is 2047)

RBP=

RBP?

RBP#

RBP?

RBP=x

(see Description of

Arguments)

BERT Error Insert BKE=

1 byte, value of

0 or 1

Command only.

Valid only in CDM-570A Compatible Mode (CMO=1).

Inserts 1 error in the form x, where:

x=1

Example: <0/BKE=1

BKE=

BKE?

BKE#

N/A

BKE=x

(see Description of

Arguments)

BERT Restart

Monitor

BRM=

None

Command only.

Valid only in CDM-570A Compatible Mode (CMO=1).

This command takes no arguments.

Restarts the BERT Monitor.

Example: <0/BRM=

BRM=

N/A

N/A

BERT Result

in bit errors

N/A

8 bytes

Query only.

Valid only in CDM-570A Compatible Mode (CMO=1).

Returns BERT monitor results in bit errors, in the form x.xxE+yy

Example: <0/BRE?

>0/BRE=8.70E+05

N/A

BRE?

BRE=x.xxE+yy