10.3.1.1.2.2.3 (CONFIG: ODU) LNB: Alarm

Set LNB Current Alarm:

Upper Lower (◄ ►,ENTER)

Use this menu to define the upper and lower limits of the LNB current ‘window.’ If the measured

LNB current falls outside this window, an alarm is generated.

Use the

◄ ► arrow keys to select Upper or Lower. Press ENTER when done.

(CONFIG: ODU) LNB: Set LNB Current Alarm ► Upper

LNB Current Alarm Upper

Limit: 200mA (◄ ►,▲ ▼,ENT)

To edit the LNB Current Alarm Upper Limit: First, use the

◄ ► arrow keys to select a digit to

edit, and then use the

▲▼arrow keys to change the value of that digit. The valid range of

current is from 50 to 600 mA. Press ENTER when done.

(CONFIG: ODU) LNB: Set LNB Current Alarm ► Lower

LNB Current Alarm Lower

Limit: 050mA (◄ ►,▲ ▼,ENT)

To edit the LNB Current Alarm Lower Limit: First, use the

◄ ► arrow keys to select a digit to

edit, and then use the

▲▼arrow keys to change the value of that digit. The valid range of

current is from 10 to 400 mA. Press ENTER when done.

10.3.1.1.2.2.4 (CONFIG: ODU) LNB: LO

BUC LO Frequency:

12000 MHz (◄ ►,▲ ▼,ENTER)

To edit the value of the LNB LO (Lockout) Frequency: First, use the

◄ ► arrow keys to select a

digit to edit, and then use the

▲▼arrow keys to change the value of that digit. The valid range is

from 3000 to 65000 MHz. Press ENTER when done.

This value is used to display the RF frequency of the modem/BUC combination. If

the default value of 00000 is entered here, then no RF frequency will be displayed

on the CONFIG: Rx Frq (Rx FREQUENCY) menu.

10.3.1.1.2.2.5 (CONFIG: ODU) LNB: Mix

LNB Frequency Mix:

High-Side Low-Side (◄ ►)

Use the

◄ ► arrow keys to define the sense of the frequency translation as High-Side or Low-

Side. Press ENTER when done.