10 (config: rx) eb/n0, 11 (config: rx) α (rx alpha filter rolloff factor), 5 config: cex (g.703 clock extension) – Comtech EF Data CDM-570A User Manual

Page 134: T.6.3.2.4.11)

Advertising
background image

CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Front Panel Operation

Revision 2

6–30

6.3.2.4.10 (CONFIG: Rx) E

b

/N

0

Eb/No Alarm Point:

02.0 dB (◄ ►,▲ ▼,ENTER)

You may define an alarm point value where, if the E

b

/N

0

falls below this value, the modem

generates a receive traffic fault.

The valid range of values is from 0.1 to 16.0 dB.

To edit the E

b

/N

0

Alarm Point, use the

◄ ►

arrow keys to select a digit, and then use the

▲▼arrow keys to change that digit. Press ENTER.

6.3.2.4.11 (Config: Rx) α (Rx Alpha Filter Rolloff Factor)

Rxα: .35 .12

(◄ ►,ENT)

Use the

◄ ►

arrow keys to select an Rx Alpha Filter Rolloff Factor (Rxα) of .35 or .12. Press

ENTER.

.35 is the default Rx Alpha Filter Rolloff Factor (Rxα).

Set the Rxα to .35 when the Txα of the received signal is 0.25 or 0.35.

Set the Rxα to .12 when the Txα of the received signal is .05, .10, .15, or .20.

When operating in CDM-570 Compatible Mode, the Rxα is fixed to the default

value of .35. Selection of this feature and its options becomes disabled and

unavailable. See Sect. 6.2 for further information.

6.3.2.5 CONFIG: CEx (G.703 Clock Extension)

G703 Clock Extend: None

TxLock RxEnable (◄ ►,ENT)

Use the

◄ ►

arrow keys to select None, TxLock, or RxEnable. Press ENTER. When you select

TxLock or RxEnable, the modem displays the following submenu:

Clk Extend Interface: T1

E1Bal E1Unbal (◄ ►,ENTER)

Use the

◄ ►

arrow keys to select T1, E1Bal, or E1Unbal as the G.703 Clock Extension interface.

Press ENTER.

Advertising