MN-CDM570A

CDM-570A/570AL ODU (Transceiver, BUC, LNB) Operation

Revision 2

10–46

10.3.1.2.2 MONITOR: ODU

Outdoor Unit Monitor:

BUC LNB (◄ ►,ENTER)

The screen shots that follow depict sample configurations – the actual values and

settings will vary and they are dependent on the ODU configuration in use. Typical

for all nested screens, press ENTER or CLEAR to return to the Outdoor Unit Monitor

submenu.

Use the

◄ ► arrow keys to select BUC or LNB, and then press ENTER.

10.3.1.2.2.1 (MONITOR: Outdoor Unit Monitor) BUC

BUC:DC=47.8V,3.25A SW=05

T=+38C PLL=Flt Pwr=02.1W

This read-only screen displays the following parameters:

Display Line Item

Description

Top

DC

(DC Power) If a BUC supply is installed, menu displays measured BUC

supply voltage and load current, measured at the Tx-IF connector.

SW

If BUC FSK is enabled, menu displays the M&C software version of the

BUC.

Bottom

T

(Temperature) If BUC FSK is enabled, menu displays BUC ambient

temperature in °C.

PLL

If BUC FSK is enabled, menu displays the fault status of the BUC PLL

synthesizers.

Pwr

(Output Power) If BUC FSK is enabled, menu displays the output power

as measured by the BUC power monitor.

10.3.1.2.2.2 (MONITOR: Outdoor Unit Monitor) LNB

LNB Voltage: 13.1 volts

LNB Current: 235 mA(ENT)

This read-only screen displays the LNB Voltage and LNB Current parameters.