CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Rear Panel Connectors and Pinouts

Revision 2

3–20

1.

Plug the user-supplied, male keyed DC power lead connector into the mating female

connector until the lock tab engages. Number 18 AWG minimum wires are recommended.

2.

Connect the user-supplied DC power leads to the power source.

3.

Energize the DC power source to turn the modem ON.

3.3.3.2.2 Optional DC Operation – Replace the DC Power Fuses

For optional DC operation, the modem requires two different fuses that are contained within

the press-fit fuse holder.

Figure 3-11. Replace the Optional DC Chassis Fuses

Do these steps (Figure 3-11):

WARNING! DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING!

1.

Unseat the fuse holder from the IEC power module:

Pry the holder outward from the module.

Pull the holder straight out, and then swing the holder away from the module.

2.

Remove and replace the 20mm Slo-Blo fuses as needed.

CAUTION – FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES

WITH THE CORRECT TYPE AND RATING.

Use T3.15A fuses for units without a BUC

Use T8A fuses for units with a BUC.

3.

Reseat the fuse holder in the IEC power module.