Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

Rx Demod

Acquisition Sweep

Width

RSW=

3 bytes

Command or Query.

Sets or returns Rx ± acquisition sweep range of demodulator in the form xxx,

where:

xxx = value, in kHz...

For CDM-570A From ±1 to ±32 kHz (rates<625 ksym/second)

For CDM/R-570AL From ±1 to ±200 kHz (rates ≥625 ksym/second)

Note: When the modem is in CNC mode (CNM>0) and Rx Symbol Rate<64ksps,

acquisition sweep range is limited from ±1 to ±(Rx_Symbol Rate / 2) kHz

Example: <0/RSW=009 (±9 kHz)

RSW=

RSW?

RSW*

RSW#

RSW?

RSW=xxx

(see Description of

Arguments)

Rx Alpha

RXA=

1 byte,value of 0 or

1

Command or Query.

Valid only in CDM-570A Compatible Mode (CMO=1).

Sets or returns Rx Filter Rolloff Factor in the form x, where:

0 = 0.35

1 = 0.12

Example: <0/RXA=0 (0.35 Tx filter rolloff factor)

RXA=

RXA?

RXA#

RXA?

RXA=x

(see Description of

Arguments)

Rx Buffer Size

RBS=

1 byte,

value of 0 thru 9

Command or Query.

Sets or returns Rx buffer size in the form x, where:

0 = Buffer disabled (Clock mode = Rx satellite)

1 = ±1024 bits

2 = ±2048 bits

3 = ±4096 bits

4 = ±8192 bits

5 = ±16384 bits

6 = ±32768 bits

7 = ±128 bits

8 = ±256 bits

9 = ±512 bits

Example: <0/RBS=0

RBS=

RBS?

RBS*

RBS#

RBS?

RBS=x

(same format as

command

argument)

ReCenter Buffer

RCB=

None

Command only.

Forces the software to recenter the receive Plesiochronous/Doppler buffer.

This command takes no arguments.

Example: <0/RCB=

RCB=

RCB?

RCB*

RCB#

N/A

N/A