2 ac operation – chassis power and fusing – Comtech EF Data CDM-570A User Manual

Page 78

Advertising
background image

CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Rear Panel Connectors and Pinouts

Revision 2

3–16

3.3.2.2 AC Operation – Chassis Power and Fusing

Feature

Description

1

On / Off Switch

2

Press-fit Fuse Holder

3

IEC Three-prong Connector

AC Power Specifications

AC Consumption

CDM-570AL L-Band:

Without Optional Packet Processor, CnC, or BUC Power Supply: 29 Watts typical, 32 Watts

maximum

With Optional Packet Processor; without CnC or BUC Power Supply: 42 Watts typical

With Optional Packet Processor and CnC; without BUC Power Supply: 48 Watts maximum

With Optional Packet Processor, CnC, and 150 Watt @50°C, 180 Watt @30°C BUC Power

supply: 250 Watts (maximum)

CDM-570A 70/140 MHz:

Without Optional Packet Processor or CnC: 29 Watts typical, 32 Watts maximum

With Optional Packet Processor; without CnC: 42 Watts typical

With Optional Packet Processor and CnC: 48 Watts maximum

Typical measured VA, Power Factor and power data:

CDM-570AL L-Band:

240V 50 Hz Power Factor = 0.44, 65VA, 29 Watts

110V 60 Hz Power Factor = 0.55, 50VA, 28 Watts

CDM-570A 70/140 MHz:

240V 50 Hz Power Factor = 0.33, 87VA, 29 Watts

110V 60 Hz Power Factor = 0.53, 51VA, 28 Watts

Operating Voltage

Standard AC operation (CDM-570A or CDM-570AL only):

100-240 volts AC, +6%/-10% – autosensing (total absolute max. range is 90-254 volts AC)

Modem Connector

Type

IEC-60320 Type C14

Mating Connector IEC-60320 Type C13
Fuse Protection

Use two (2X) 3.15A 5mm x 20mm Slo-Blo fuses for line and neutral fusing (115V AC

operation). Fuses are contained within a fuse holder that is press-fit into the body of the

IEC power module.

Figure 3-6. Modem Standard AC Chassis (CDM-570AL-IP Shown)

Advertising