3 (odu select:) monitor – Comtech EF Data CDM-570A User Manual

Page 389

Advertising
background image

CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

CDM-570A/570AL ODU (Transceiver, BUC, LNB) Operation

Revision 2

10–15

This screen shows the model and serial number for the ODU in use.

(ODU SELECT ► INFO):Transmitter

Tx: ON 5845.0MHz 10.00dB

AMP:ON Unmuted Sl:0.0

This screen shows information on the CSAT transmitter status: Tx operating state (ON or

OFF); Tx Frequency; Tx Attenuation; Amplifier state (ON or OFF); Tx Mute state (Muted or

Unmuted); and Tx Slope adjustment.

(ODU SELECT ► INFO): Receiver

Rx: ON 3570.0MHz 10.00dB

Unmuted Sl:0.0

This screen shows information on the CSAT receiver status: Rx operating state (ON or OFF); Rx

Frequency; Rx Attenuation; Rx Mute state (Muted or Unmuted); and Rx Slope adjustment.

(ODU SELECT ► INFO): LNA

LNA: On Window: 99%

Fault Logic: No-Summary

This screen shows the current state of the LNA functions: the LNA operating status (ON or

OFF); the Current Window; and Fault-Logic settings (Summary or No-Summary).

(ODU SELECT ► INFO): Misc

Cold Start: Off

Auto Fault Recovery: On

This screen shows the current state of the Cold Start and Auto Fault Recovery functions as

ON or OFF.

10.2.1.2.1.1.1.3 (ODU SELECT:) Monitor

ODU MONITOR: Tx Rx Misc

Pwr-Supp1 Pwr-Supp2 (◄ ►)

For access to real-time information displays on the ODU currently in operation, use the

◄ ►

arrow keys to select Tx, Rx, Misc, Pwr-Supp1, or Pwr-Supp2. Press ENTER when done.

The read-only screen shots that follow depict sample configurations – the actual

values and settings will vary and they are dependent on the ODU configuration in

use. Typical for all nested screens, press ENTER or CLEAR to return to the ODU

SELECT: Monitor menu.