5 monitor: stats (link statistics), 1 (monitor: link statistics) view – Comtech EF Data CDM-570A User Manual

Page 148

Advertising
background image

CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Front Panel Operation

Revision 2

6–44

When you select Yes, the modem clears the event log and returns you to the previous menu.

However, if a fault persists, the modem re-stamps the fault and generates a new log entry.

In accordance with European convention, the date appears in DAY-MONTH-YEAR

format.

6.3.3.5 MONITOR: Stats (Link Statistics)

Link Statistics: View

Clear-All Config(◄ ►,ENT)

Use the

◄ ►

arrow keys to select View, Clear-All, or Config. Press ENTER.

6.3.3.5.1 (MONITOR: Link Statistics) View

Sta198:02/11/13 10:37:32

16.0, 16.0, 9.0, 9.0(▲ ▼)

The Link Statistics Log stores up to 255 events. Use the ▲▼arrow keys to browse through the

available entries. Press ENTER or CLEAR to return to the previous menu.

The top line indicates the log entry number, and the time and date of the entry.

In accordance with European convention, the date appears in DAY-MONTH-YEAR

format.

The bottom line shows the measured and recorded statistics data: Minimum E

b

/N

0;

Average

E

b

/N

0;

Maximum TPLI; and Average TPLI. (TPLI = Transmit Power Level Increase – you must enable

AUPC to review TPLI.)

The meaning and format of the numbers is as follows:

Once you define a measurement interval (see MONITOR: Stats Config), the modem

observes E

b

/N

0

and TPLI at a once-per-second rate during this interval. At the end of the

interval, the modem calculates and records the average E

b

/N

0

and the minimum value seen

during the interval. Similarly, the modem calculates the TPLI along with the highest value seen

during the interval.

If the demod loses lock during the measurement interval, the minimum E

b

/N

0

shows ‘Loss’ rather than indicates a value. However, the average value (while

the demod was locked) will still be calculated and shown. If, on the other

hand, you unlock the demodulator for the entire measurement interval, the

average E

b

/N

0

will also show ‘Loss’. (The display shows ‘Loss, Loss’.)

If the measured values are greater than or equal to 16.0 dB, the display shows ‘16.0’.

Advertising