Comtech EF Data CDM-570A User Manual

Page 285

Advertising
background image

CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Serial-based Remote Product Management

Revision 2

8–45

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

Redundancy

State

N/A

1 bytes, 0 or 1

Query only.

Returns the redundancy state of the unit in the form x, where:

0 = Offline

1 = Online

Example: <0/RED?

>0/RED=1 (selects Online)

N/A

RED?

RED=x

(See Description of

Arguments)

Temperature

N/A

3 bytes

Query only.

Returns the unit internal temperature, in degrees C, in the form sxx, where:

s = sign (+ or –)

xx = value

Example: <0/TMP?

>0/TMP=+26

N/A

TMP?

TMP=sxx

(see Description of

Arguments)

Offline Unit

Status

N/A

6 bytes

Query only. (1:1 set-up)

Sent to the online modem of a 1:1 pair. Returns the fault status information (FLT?)

of the offline modem in the form abcdef, where:

abcdef = The FLT? response information from the offline unit

Note: This is the only way to interrogate the status of an offline modem at the

distant-end of a link.

N/A

OUS?

OUS=abcdef

(see Description of

Arguments)

Faults and

Status

N/A

6 bytes

Query only.

Returns the current highest-priority fault and status codes for the Unit

(hardware), Tx Traffic, Rx Traffic and ODU in the form abcdef, where:

a = Unit faults:

0 = No faults

1 = Power supply fault, +5 volts

2 = Power supply fault , +12 volts

3 = Power supply fault, –5 volts

4 = Reserved

5 = Power supply fault, –12 volts

6 = Tx synthesizer lock

7 = Rx 1st LO synthesizer lock

8 = Rx 2

nd

LO synthesizer Lock

9 = Ref PLL lock

A = Reserved

B = Reserved

C = Reserved

D = Reserved

E = Packet Processor

F = Reserved

N/A

FLT?

FLT=abcdef

(see Description of

Arguments)

Advertising