CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Ethernet-based Remote Product Management

Revision 2

7–7

Configure HyperTerminal as follows:

Make sure that your connection is

made using TCP/IP (Winsock)

instead of COM1 or COM2, as

shown at the near right.

The Host address is the modem’s

Traffic/Management IP Address in

the form xxx.xxx.xxx.xxx.

The Port number must be 23

when the optional Packet

Processor is INSTALLED, or 7023

when using a Base Modem

without Packet Processor.

ASCII Setup (File  Properties  Settings  ASCII Setup): Check the "Send line ends with

line feeds" option in the ASCII Sending section, and the "Append line feeds to incoming line

ends" option in the ASCII Receiving section, as shown at the far right.

An example of login and remote command/query execution, when using HyperTerminal as the

Telnet interface, is shown here: