Comtech EF Data CDM-570A User Manual

Page 256

Advertising
background image

CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Serial-based Remote Product Management

Revision 2

8–16

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

AUPC Parameters

APP=

6 bytes

Command or Query.

Not valid in Manual mode.

Sets or returns AUPC operating parameters, in the form abc.cd, where:

a = Defines action on max. power condition.

0 = do nothing

1 = generate Tx alarm

b = Defines action on remote demod unlock.

0 = go to nominal power

1 = go to max power

c.c = Target E

b

/N

0

value, for remote demod, from 0.0 to 14.9 dB, where numbers

>9.9 use hex representation for the 1 st character, i.e., 14.9 is coded as E.9.

d = Max increase in Tx Power permitted, from 0 to 9 dB

Example: <0/APP=015.67 (Sets no alarm, max power, 5.6 dB Target and 7 dB power

increase.)

In IP-ACM mode:

a=Defines action on max. power condition.

0 = do nothing

1 = generate Tx alarm

2=generate Tx alarm when mimimum ModCod is reached

b=Defines action on remote demod unlock.

0 = go to nominal power

1 = go to max power

2=hold

c.c = Max increase in Tx Power permitted, from 0.0 to 9.9 dB OR when CnC mode is

on, from 0.0 to 3.0 dB

d = unsued (always 0)

APP=

APP?

APP*

APP#

APP?

APP=abc.cd

(see Description of

Arguments)

Remote Eb/No

N/A

4 bytes

Query only.

Returns the value of Eb/No of the remote demod in the form xx.x, where:

xx.x = 02.0 to 16.0

Response is 99.9 if remote demod unlocked.

Response is xx.x if EDMAC is disabled.

Example: <0/REB?

>0/REB=12.4

Note: For values >16.0 dB, the response = 16.0

N/A

REB?

REB=xx.x

(see Description of

Arguments)