8–48

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

CnC

Freq Offset

Monitor

N/A

6 bytes

Query only.

Valid only in CDM-570A Compatible Mode (CMO=1).

Calculates an estimated frequency offset, in kHz, between the interferer and the

desired power when CnC is enabled.

Examples: <0/CFM?

1) >0/CFM=+001.0 (1 kHz)

2) >0/CFM=9999.9 (not locked or CnC not enabled)

N/A

CFF?

CFF=xxxxxx

(see Description of

Arguments)

CnC Power

Ratio Monitor

N/A

6 bytes

Query only.

Valid only in CDM-570A Compatible Mode (CMO=1).

When CnC is enabled and the modem is locked, ratio (in dB) between the

interferer and the desired power is monitored, with 0.1dB resolution.

Examples: <0/CPR?

1) >0/CPR=+02.8 (interferer>desired) (format = sdd.d)

2) >0/CPR=LT11.0 (less than –11.0 dB)

3) >0/CPR=GT19.0 (greater than +19.0 dB)

4) >0/CPR=9999.9 (not locked or CnC not enabled)

5) >0/CPR=AUTO (in CnC-APC mode)

N/A

CPR?

CPR=xxxxxx

(see Description of

Arguments)

CnC PSDR

N/A

5 bytes

Query only.

Valid only in CDM-570A Compatible Mode (CMO=1).

When CnC is enabled and the modem is locked, ratio (in dB) between the

interferer and the desired power is monitored, with 0.1 dB resolution.

Examples: <0/PSD?

1) >0/PSD=+02.8 (interferer>desired) (format = sdd.d)

2) >0/PSD=999.9 (not locked or CnC not enabled)

3) >0/PSD=AUTO (in CnC-APC mode)

N/A

PSD?

PSD=xxxxx

(see Description of

Arguments)

CnC-APC Bit

Error Rate

N/A

4 bytes

Query only.

Valid only in CDM-570A Compatible Mode (CMO=1).

Returns the value of CnC-APC BER in the form xE

-c

, where:

x = value

E

-c

= Exponent.

Returns 9999 if unit is not in CnC-APC mode or if there is an APC frame sync

error.

BER is measured in frame UW.

Example: <0/ABE?

>0/ABE=8E-5

N/A

ABE?

ABE= xE

-c

(see Description of

Arguments)

CnC-APC BER

Reset

ABR=

None

Command only.

Valid only in CDM-570A Compatible Mode (CMO=1).

This command takes no arguments.

Restarts CnC-APC BER measurement.

ABR=