Comtech EF Data CDM-570A User Manual

Page 346

Advertising
background image

CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Optional Packet Processor - Serial/Telnet CLI Operation

Revision 2

9–50

9.3.8.1.7 Satellite Modem > Configuration > Block Up Converter (BUC)

Configuration

Open the nested Block Up Converter (BUC) Configuration page from the Configuration page.

Figure 9-33. Block Up Converter (BUC) Configuration

Selection

Hot Key Description

BUC Address

A

Set an address for the BUC in the range from 1 to 15.

BUC Communications

M

Toggle to set operation as Enabled or Disabled.

BUC RF Output

R

BUC DC Power

W

BUC 10 MHz Reference

P

BUC Current Alarm Upper

Limit (mA)

H

Set a value in the range from 500 to 4000.

BUC Current Alarm Lower

Limit (mA)

C

Set a value in the range from 0 to 3000.

BUC LO Frequency (MHz)

F

Set a value in the range from 3000 to 65000. Set this value to 0 to

disable.