Comtech EF Data CDM-570A User Manual
Page 342
![background image](/files/778757/content/doc342.png)
CDM-570A/570AL Satellite Modem with Optional Packet Processor
MN-CDM570A
Optional Packet Processor - Serial/Telnet CLI Operation
Revision 2
9–46
Selection
Hot Key Description
Recenter Rx Buffer
C
Select to force re-centering of the Plesiochronous/Doppler buffer.
Rx Clock Inversion
A
Select the Rx clock inversion type:
1 – Normal
2 – Inverted
Rx Filter Rolloff
E
Select the Rx alpha filter rolloff:
1 – 0.35
2 – 0.25
9.3.8.1.3 Satellite Modem > Configuration > Framing Mode Configuration
Open the nested Framing Mode Configuration page from the Configuration page.
Figure 9-29. Framing Mode Configuration
Selection
Hot Key Description
Framing Mode
F
Select the Framing Mode:
1 – Unframed
2 – EDMAC Framing
3 – EDMAC-2 Framing
EDMAC Mode
D
Select the EDMAC Framing Mode:
1 – Unframed
2 – EDMAC Framing
3 – EDMAC-2 Framing
EDMAC Slave Address Range
V
Set a value from 10 to 9990 in multiples of ten.
AUPC
A
Select the AUPC operation:
1 – Enable
2 – Disable
Max Power Reached Action
R
Select the action:
1 – No_Action
2 – Generate_TX_Alarm
Remote Demod Unlock Action
U
Select the action:
1 – Nominal_Power
2 – Maximum_Power
Target E
b
/N
0
of Remote Demod
(db)
E
Set a value from 0.0 to 9.9.
Maximum Power Limit
M
Set a value from 0 to 9.