2 (config: odu) buc: dc-power, 3 (config: odu) buc: 10mhz, 4 (config: odu) buc: alarm – Comtech EF Data CDM-570A User Manual

Page 416

Advertising
background image

CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

CDM-570A/570AL ODU (Transceiver, BUC, LNB) Operation

Revision 2

10–42

(CONFIG: ODU) BUC: M&C-FSK ►TX-On/Off

BUC RF Output:

On Off (◄ ►,ENTER)

Use the

◄ ► arrow keys to select the BUC RF Output as On or Off. Press ENTER when done.

10.3.1.1.2.1.2 (CONFIG: ODU) BUC: DC-Power

BUC DC Power:

On Off (◄ ►,ENTER)

Use the

◄ ► arrow keys to select the BUC DC Power as On or Off. Press ENTER when done.

10.3.1.1.2.1.3 (CONFIG: ODU) BUC: 10MHz

BUC 10MHz Reference:

On Off (◄ ►,ENTER)

Use the

◄ ► arrow keys to select the BUC 10 MHz Frequency Reference as On or Off. Press

ENTER when done.

10.3.1.1.2.1.4 (CONFIG: ODU) BUC: Alarm

Set BUC Current Alarm:

Upper Lower (◄ ►,ENTER)

Use this menu to define the upper and lower limits of the BUC current ‘window.’ If the

measured BUC current falls outside this window, an alarm is generated.

Use the

◄ ► arrow keys to select Upper or Lower, and then press ENTER.

(CONFIG: ODU) BUC: Set BUC Current Alarm ► Upper

BUC Current Alarm Upper

Limit:1200mA (◄ ►,▲ ▼,ENT)

To edit the BUC Current Alarm Upper Limit: First, use the

◄ ► arrow keys to select a digit to

edit, and then use the

▲▼arrow keys to change the value of that digit. The valid range of

current is from 500 to 4000 mA. Press ENTER when done.

(CONFIG: ODU) BUC: Set BUC Current Alarm ► Lower

BUC Current Alarm Lower

Limit:1200mA (◄ ►,▲ ▼,ENT)

To edit the BUC Current Alarm Lower Limit: First, use the

◄ ► arrow keys to select a digit to