Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

Software

Information

(continued)

FW-0020687-,1.1.22,11/08/13

FW-0020688-,1.1.5 ,11/05/13

FW-0000516-,1.1.1 ,19/01/11

Software Revision N/A

34-37 bytes

Query only.

Returns the value of the internal software revision installed in the unit, in the form:

Boot:x.y.z Bulk1:x.y.z Bulk2:x.y.z or

Boot:x.y.zz Bulk1:x.y.zz Bulk2:x.y.zz

N/A

SWR?

SWR=Boot:x.y.zz

Bulk1:x.y.zz

Bulk2:x.y.zz

(see description

of arguments)

Serial Number

N/A

9 bytes

Query only.

Returns the unit’s 9-digit serial number.

Example: <0/SNO?

>0/SNO=176500143

N/A

SNO?

SNO=xxxxxxxxx

(see Description of

Arguments)

Fractional CnC 90-

day Counter

N/A

7 bytes

Query Only.

Returns the number of seconds that Fractional CnC license has been used in 1

year period since the last time the CnC counter was reset to 0.

Example: <0/FCC?

>0/FCC=0000455 (indicating 455 seconds)

N/A

FCC?

=xxxxxxx

(see Description of

Arguments)

Modem Operational

Full Year Counter

N/A

8 bytes

Query Only.

Returns the number of seconds that the unit has been powered on since last reset

of the counter. The counter resets to 0 when it reaches 31536000 seconds

(seconds in 365 days).

Example: <0/SFCF?

>0/FCF=00001342 (indicating 1342 seconds)

N/A

FCF?

=xxxxxxxx

(see Description of

Arguments)