Comtech EF Data CDM-570A User Manual

Page 287

Advertising
background image

CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Serial-based Remote Product Management

Revision 2

8–47

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

Faults and

Status (continued)

d = ODU status:

0 = No ODU faults

1 = BUC PLL

2 = Reserved

3 = BUC current

4 = Reserved

5 = BUC voltage

6 = Reserved

7 = LNB current

8 = Reserved

9 = LNB voltage

A = Reserved

B = BUC temperature

C = Reserved

D = BUC software checksum

E = Reserved

F = Reserved

e = Change in fault status since last poll:

0 = No fault changes since last poll

1 = Faults have occurred

f = Change in unit configuration since last poll:

0 = No configuration changes since last poll

1 = Configuration changes have occurred

CnC

Ratio Monitor

N/A

4 bytes

Query only.

Valid only in CDM-570A Compatible Mode (CMO=1).

Monitors the ratio, in dB, between the interferer and the desired power when CnC

is enabled and the modem is locked.

Examples: <0/CRM?

1) >0/CRM=+02 (interferer>desired) (format = sdd)

2) >0/CRM=LT11 (less than –11 dB)

3) >0/CRM=GT11 (greater than +11 dB)

4) >0/CRM=99.9 (not locked or CnC not enabled)

5) >0/CRM=AUTO (in CnC-APC mode)

N/A

CRM?

CRM=xxxx

(see Description of

Arguments)

CnC

Delay Monitor

N/A

6 bytes

Query only.

Valid only in CDM-570A Compatible Mode (CMO=1).

Monitors the delay, in microseconds, of the interferer when CnC is enabled and

the modem is locked.

Examples: <0/CDM?

1) >0/CDM=229500 (229.5 ms)

2) >0/CDM=999999 (not locked or CnC not enabled)

N/A

CDM?

CDM=xxxxxx

(see Description of

Arguments)

Advertising