2 (odu select:) info (information) – Comtech EF Data CDM-570A User Manual

Page 388

Advertising
background image

CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

CDM-570A/570AL ODU (Transceiver, BUC, LNB) Operation

Revision 2

10–14

(ODU CONFIG ► MISC:) XRef (External Reference)

ExternalRef Fault Logic:

Summary No-Summary (◄ ►)

Use the

◄ ► arrow keys to select Summary or No-Summary, and then press ENTER.

The CSAT automatically locks to an external 5 or 10 MHz reference

independent of the state of this selection. This selection determines

whether or not the Summary Fault Relay is activated if the CSAT loses lock

with the external reference.

(ODU CONFIG ► MISC:) Ref-Adjust

Internal Ref Adjustment:

087 (▲ ▼,ENT)

Use the

▲▼arrow keys to select an Internal 10MHz Reference setting value from 000

to 255. Press ENTER when done.

The Internal Reference is adjusted in the factory to be very accurate with

the default setting of 087. Use this feature as needed to compensate for

the long-term frequency drift of the oscillator.

(ODU CONFIG ► MISC:) RTC (Real-Time Clock)

Sync ODU RTC to Lcl RTC:

Yes No (◄ ►,ENT)

Use the

◄ ► arrow keys to select Yes to cause the CSAT RTC (Real Time Clock) to

synchronize with the modem RTC, or No. Press ENTER when done.

10.2.1.2.1.1.1.2 (ODU SELECT:) Info (Information)

INFO: Model Transmitter

Receiver LNA Misc (◄ ►)

For read-only information on the ODU as currently configured for operation, use the

◄ ►

arrow keys to select Model, Transmitter, Receiver, LNA, or Misc. Press ENTER when done.

The read-only screen shots that follow depict sample configurations – the actual

values and settings will vary and they are dependent on the ODU configuration in

use. Typical for all nested screens, press ENTER or CLEAR to return to the ODU

SELECT: Info menu.

(ODU SELECT ► INFO): Model

CSAT-5060/010 V2.09

SERIAL # 00225 (ENT)