Page 419

Advertising
background image

CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

CDM-570A/570AL ODU (Transceiver, BUC, LNB) Operation

Revision 2

10–45

10.3.1.2 (SELECT:) Monitor

MONITOR: Alarms Rx-Params

Event-Log Stats AUPC ODU

For ODU operation, use the

◄ ► arrow keys to select Alarms or ODU, and then press ENTER.

10.3.1.2.1 MONITOR: Alarms

Live Alarms:Unit Receive

Transmit ODU (◄ ►,ENTER)

The CDM/R-570AL uses a system of Fault Prioritization. This system cuts down

significantly on unwanted and irrelevant fault reporting. Only the highest priority fault

is displayed in each category. For example, if the demodulator is unlocked, it is

irrelevant if there are other Rx faults present. If the demodulator then locks, but there is

a fault of a lower priority present, this will then be displayed. This also holds true for the

faults reported via the remote control.

SUMMARY OF PRIORITIZED ODU FAULTS

ODU Status

1) BUC PLL lock fault
2) BUC Current Out of Limits
3) BUC Voltage Out of Limits
4) LNB Current Out of Limits
5) LNB Voltage Out of Limits
6) BUC Temperature Alarm
7) BUC Software Checksum Error

For ODU Live Alarms, use the

◄ ► arrow keys to select ODU, and then press ENTER.

10.3.1.2.1.1 (MONITOR: Live Alarms) ODU

ODU Alarms: BUC Current

Out of Limits (ENT)

ODU Alarms: None

(ENT)

This read-only screen indicates if there are any ODU Alarms present. If a prioritized fault is

present it is displayed here (as per the SUMMARY OF PRIORITIZED ODU FAULTS table). If not,

the screen displays ‘

None

’.

Press ENTER or CLEAR to return to the previous menu.