8–49

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

CnC-APC

Frame Error

Rate

N/A

4 bytes

Query only.

Valid only in CDM-570A Compatible Mode (CMO=1).

Returns the value of CnC-APC FER in the form xE

-c

, where:

x = value

E

-c

= Exponent.

Returns 9999 if modem is not in CnC-APC mode or if there is an APC frame sync

error.

Example: <0/AFE?

>0/AFE=8E-2

N/A

AFE?

AFE= xE

- c

(see

Description of

Arguments)

CnC-APC FER

Reset

AFR=

None

Command only.

Valid only in CDM-570A Compatible Mode (CMO=1).

This command takes no arguments.

Restarts CnC-APC FER measurement.

AFR=

N/A

N/A

CnC-APC

Activate/Suspend

APC=

1 byte, 0 thru 2

Command only.

Valid only in CDM-570A Compatible Mode (CMO=1).

Activates or suspends APC operation in the form x, where:

0 = no action

1 = Activate APC

2 = Suspend APC

APC=

N/A

N/A

CnC-APC State

N/A

2 bytes

Query only.

Valid only in CDM-570A Compatible Mode (CMO=1).

Returns the state of APC operation in form xx, where:

00 = APC is not active

01 = No Solution

02 = OK - ReBalance Done

03 = OK(Partial): CnC Ratio approaches limit

04 = OK(Partial): Local power approaches miminum value (-25 dBm for IF band)

05 = OK(Partial): Local power approaches minimum value (-40 dBm for L-Band)

06 = OK(Partial): Local power approaches maximum value (0 dBm)

07 = OK(Partial): Local power approaches limit set by max power level increase

08 = OK(Partial): Distant power approaches miminum value (-25 dBm for IF band)

09 = OK(Partial): Distant power approaches minimum value (-40 dBm for L-Band)

10 = OK(Partial): Distant power approaches maximum value (0 dBm)

11 = OK(Partial): Distant power approaches limit set by max power level increase

12 = OK(Partial): Incomplete

13 = No APC Frame Sync

14 = CnC Ratio Problem

15 = Local EbNo too high

16 = Distant EbNo too high

17 = Distant End ReBalance failed

N/A