D.2.7.1 managed switch mode troubleshooting – Comtech EF Data CDM-570A User Manual

Page 489

Advertising
background image

CDM-570L/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Appendix D

Revision 2

D–31

D.2.7 Troubleshooting High Performance Packet Processor Operation

The CDM-IP comes with a variety of diagnostic tools to aid in identifying the traffic path going

into and out of the CDM-IP modem. This troubleshooting section shows how to use some of

these tools and also identifies several problem scenarios commonly encountered when first

setting up two CDM-IP modems.

If following these troubleshooting steps fails to resolve the problem, contact Comtech EF Data

Product Support for further assistance:

+1.240.243.1880

+1.866.472.3963 (toll free USA)

D.2.7.1 Managed Switch Mode Troubleshooting

Follow these troubleshooting steps if unable to successfully send traffic in Managed Switch

Mode:

Scenario Problem

Action

1

No Ping response from the

locally connected PC to the

CDM-IP Ethernet port.

ICMP response is:

Request timed out

A. Verify correct IP Address/subnet on PC and CDM-IP.

B. Verify Ethernet connection – cables, PC, Layer 2 hub or switch,

and CDM-IP should have Ethernet activity LED lit.

Note: A PC must be connected to the CDM-IP using a Layer 2

hub or switch, or an RJ45 crossover cable.

When the CDM-IP Ethernet port senses an Ethernet

connection, the CLI displays:

Ethernet Interface UP

If the connection is broken, the CLI displays:

Ethernet Interface DOWN

2

No Ping response from the

locally connected PC to the

remote CDM-IP or remote PC.

ICMP response is:

Request timed out

A. Verify both CDM-IP’s are in Managed Switch Mode.

B. Verify IF link between modems for proper settings and carrier

quality (Rx signal level, E

b

/N

0

, etc.). It is possible that there is a

spectrum inversion, particularly if you are using the CDM-IP

with RF converter equipment. If this is the case, the signal level

& E

b

/N

0

may be OK, but no data will be received. To correct

this, invert the Tx and Rx Spectrum on one of the CDM-IPs.

C. Use Windows Command-line to send a constant ping from the

User PC 1 ‘ping 172.16.10.2 –t’ to User PC 2.

From the CLI Main Menu:

Select the Operations and Maintenance page [I], and then

select the Diagnostics page [G].