3 select: monitor, 1 monitor: alarms – Comtech EF Data CDM-570A User Manual

Page 145

Advertising
background image

CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Front Panel Operation

Revision 2

6–41

6.3.3 SELECT: Monitor

MONITOR: Alarms Rx ACM

Event Stats AUPC CnC ODU

Use the

◄ ►

arrow keys to select a parameter (ODU is available only with the CDM-570AL).

Press ENTER.

6.3.3.1 MONITOR: Alarms

IMPORTANT NOTE – The CDM/R-570ALuses a system of Fault Prioritization, where the

modem will display only the highest priority fault in a designated category. This cuts

down significantly on unwanted and irrelevant fault reporting.

For example, if the demodulator is unlocked, then it is irrelevant if there are other

Rx faults present. However, if the demodulator then locks while a lower-priority

fault is present, then the modem will display that fault. This also applies for faults

reported via remote control.

For CDM/R-570ALunits with ODUs, see Chapter 10. CDM-570A/570AL ODU

(TRANSCEIVER, BUC, LNB) M&C OPERATIONS for details on selecting this submenu

and the listing of prioritized ODU faults.

Live Alarms:Unit Receive

Transmit ODU (◄ ►,ENTER)

For 70/140 MHz or L-Band modems without ODUs, use the

◄ ►

arrow keys to select Unit,

Receive, or Transmit. Press ENTER.

LIST OF PRIORITIZED FAULTS

Unit Faults

Tx Traffic Status

Rx Traffic Status

1) Power supply fault, +5 volts
2) Power supply fault, +12 volts
3) Power supply fault, –5 volts
4) Power supply fault, –12 volts
5) Tx synthesizer lock
6) Rx 1

st

LO synthesizer lock

7) Rx 2

nd

LO synthesizer lock

8) Reference PLL lock
9) PaP Heartbeat

1) No clock from terrestrial interface
2) Tx PaP ETH Link Down
3) Tx FIFO slip
4) Loss of Signal on G.703 interface
5) Loss of External Reference
6) AUPC upper limit reached

7) AIS detected on incoming data

(from terrestrial direction)

8) Bipolar violation on G.703 interface
9) BUC Alarm (if attached)

1) Demodulator unlocked
2) AGC Alarm - signal out of range
3) APC Frame sync alarm
4) EDMAC Frame sync alarm
5) APC Band mismatch alarm
6) Buffer Underflow
6) Buffer Overflow
7) E

b

/N

0

alarm

8) LNB Alarm (if attached)
9) AIS detected on incoming data

(from satellite direction)

Advertising