For the CDM-570A only: On the bottom line, select use use the

▲▼

arrow keys to select set

Act? (Activate?) as Y or N (where Y? N is equivalent to Suspend for L-Band units).

Mode: APC,Side-A, C-band

Act?Y APC is not active

Press ENTER when done.

For either unit, the message on the bottom line can be any one of the following:

Displayed Message

Expanded Meaning

OK-ReBalance Done

Full re-balance was achieved

OK(P)CnCRatioLim

Partial re-balance, limited by CnC ratio approaching its working limit

OK(P)-LocalPwrMin

Partial re-balance, limited by local power approaching its lower limit

OK(P)-LocalPwrMax

Partial re-balance, limited by local power approaching its upper limit

OK(P)-LocalPwrLim

Partial re-balance, limited by local power approaching TPLI

max

OK(P)-DistPwrMin

Partial re-balance, limited by distant power approaching its lower limit

OK(P)-DistPwrMax

Partial re-balance, limited by distant power approaching its upper limit

OK(P)-DistPwrLim

Partial re-balance, limited by local power approaching TPLI

max

OK(P)-Incomplete

Partial re-balance, algorithm did not fully converge

No APC Frame Sync Communication not possible – no APC frame sync
Locl EbNo too high

The local Eb/No is too high (>16 dB) to determine re-balance params

Dist EbNo too high

The distant Eb/No is too high (>16 dB) to determine re-balance params

DistEnd ReBal fail

The distant end failed to re-balance

DistEnd NoResponse

The distant end failed to respond

Fail-CalcMismatch

No Re-balance - the solution calculated by each end does not match

CnC Ratio too high

The CnC ratio is too high (>9 dB) for re-balancing to be attempted

LoclMargin too low

There is insufficient local Eb/No margin for an APC re-balance

DistMargin too low

There is insufficient local Eb/No margin for an APC re-balance

Rx DataRate<64kbps

The Rx data rate needs to be 64 kbps or higher for APC

Rx DataRate<64kbps

The Tx data rate needs to be 64 kbps or higher for APC

Local RSL too low

The local RSL is below the minimum for the operating symbol rate

Dist RSL too low

The distant RSL is below the minimum for the operating symbol rate

If the message shown begins with OK, then after approximately 5 seconds, the display

changes as per the following example:

CnC-APC:Activate Suspend

No APC Frame Sync

At this point, as indicated on the bottom line of the display, CnC-APC is active.