CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Serial-based Remote Product Management

Revision 2

8–54

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

BUC Software

Version

N/A

2 bytes

Query only.

Returns the BUC software version in the form xx.

When unavailable, response is 00

Note: Command valid only when the FSK and BUC power are turned On.

Example: <0/BSV?

>0/BSV=05 (Software version 05)

N/A

BSV?

BSV=xx

(see Description of

Arguments)

BUC Temperature N/A

3 bytes

Query only.

Returns BUC temperature is returned, in the form sxx, where:

s = sign (+ or –)

xx = value

When unavailable, response is –99

Note: This query is valid only when the FSK and BUC power are turned On.

Example: <0/BUT?

>0/BUT=–13 (BUC temperature is –13 degrees C)

N/A

BUT?

BUT=sxx

(see Description of

Arguments)