6–37

6.3.2.9 CONFIG: Msk (Alarm Masking)

CDM/R-570AL(L-Band) unit:

CDM-570A (70/140 MHz) unit:

Use the

◄ ►

arrow keys to select Transmit, Receive, Ref, BUC (CDM/R-570ALonly), or LNB

(CDM/R-570ALonly). Press ENTER.

6.3.2.9.1 (CONFIG: Alarm Mask) Transmit

Tx Alarm Mask: Tx-FIFO

G703BPV TxAIS G703LOS ◄ ►

Use the

◄ ►

arrow keys to select a parameter. Press ENTER.

Each choice displays a submenu similar to the TX-FIFO submenu:

Tx-FIFO Alarm:

Active Masked (◄ ►,ENT)

Typical for each Tx Alarm submenu, use the

◄ ►

arrow keys to select Active or Masked. Press

ENTER.

When you select Masked, the modem generates no alarm. When you select Active, the modem

generates a fault. For example, for the preceding TX-FIFO Tx Alarm Mask, with the mask set to

Active the modem generates a Transmit Traffic fault whenever the transmitter sees that the

Transmit FIFO has slipped.

6.3.2.9.2 (CONFIG: Alarm Mask) Receive

Rx Alarm Mask: AGC Eb/No

Rx-AIS Buffer (◄ ►,ENT)

Use the

◄ ►

arrow keys to select AGC, E

b

/N

0

, Rx-AIS, or Buffer. Press ENTER. Each choice

displays a submenu similar to the AGC submenu:

AGC Alarm:

Active Masked (◄ ►,ENT)

Typical for each Rx Alarm submenu, use the

◄ ►

arrow keys to select Active or Masked. Press

ENTER.

When you select Masked, the modem generates no alarm. When you select Active, the modem

generates a fault. For example, for the preceding AGC Alarm Mask, with the mask set to Active

the modem generates a Receive Traffic fault whenever the demodulator sees that the composite

Alarm Mask: Transmit

Receive Ref (◄ ►)

Alarm Mask: Transmit

Receive Ref BUC LNB (◄ ►)