Comtech EF Data CDM-570A User Manual

Page 265

Advertising
background image

CDM-570A/570AL Satellite Modem with Optional Packet Processor

MN-CDM570A

Serial-based Remote Product Management

Revision 2

8–25

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

Internal 10MHz

Reference

Adjustment

ADJ=

4 bytes, numeric Command or Query.

Sets or returns fine adjustment of the modem Internal 10MHz Reference in the

form sddd, where:

s = sign (+ or –), and

ddd = value from 000 to 999

ADJ=

ADJ?

ADJ*

ADJ#

ADJ?

ADJ=sddd

(see Description of

Arguments)

Warm-up Delay

WUD=

1 byte,

value 0 or 1

Command or Query.

Sets or returns Warm-up Delay for internal frequency reference (OCXO) in the form

x, where:

0 = Disabled (instant on – no delay for OCXO to reach temperature)

1 = Enabled (unit waits until OCXO reaches correct temperature)

Example: <0/WUD=1 (selects Warm-up Delay)

WUD=

WUD?

WUD*

WUD#

WUD?

WUD=x

(see Description of

Arguments)

Countdown

CTD=

3 bytes

Command or Query.

As a command, only takes the argument 000. Truncates the Warm-up delay

period to zero and forces the unit into ‘instant-on’ mode. For example, CTD=000

terminates the warm-up delay.

As a query, returns the Warm-up Delay countdown, in seconds remaining. Range

is from 000 to 200 seconds.

For example: <0/CTD?

>0/CTD=067 (means the unit will wait another 67 seconds before it

enters its operational state)

CTD=

CTD?

CTD*

CTD#

CTD?

CTD=xxx

(see Description of

Arguments)

Unit Test Mode

TST=

1 byte,

value of 0 thru 6

Command or Query.

Sets or returns the CDM/R-570AL Test Mode, where:

0 = Normal Mode (no test)

1 = IF Loopback

2 = Digital Loopback

3 = I/O Loopback

4 = RF Loopback

5 = Tx CW

6 = Tx Alternating 1,0 Pattern

Example: <0/TST=1 (IF Loopback)

TST=

TST?

TST*

TST#

TST?

TST=x

(see Description of

Arguments)

Number of Unread

stored Events

N/A

3 bytes

Query only.

Returns the number, in the form xxx, of stored events which remain unread over

the remote interface.

Example: <0/NUE?

>0/NUE=126

N/A

NUE?

NUE=xxx

(see Description of

Arguments)

Advertising
This manual is related to the following products: