8–28

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

Retrieve next 5

unread Stored

Statistics

N/A

130 bytes

Query only.

Returns the oldest 5 Stored Statistics that remain unread over the remote interface.

Reply format:

{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Subbody{CR}Sub-body

where Sub-body = AA.ABB.BC.CD.Dddmmyyhhmmss:

AA.A=Minimum Eb/No during sample period.

BB.B=Average Eb/No during sample period.

C.C=Max. Tx Power Level Increase during sample period.

D.D=Average Tx Power Level Increase during sample period.

ddmmyyhhmmss = date/time stamp.

Notes:

1) If there are no new events, the unit response is RNS*.

2) If less than 5 statistics are to be retrieved, the remaining positions are padded

with zeros.

N/A

RNS?

RNS={CR}AA.ABB.

BC.CD.Dddmmyyh

hmmss{CR}AA.AB

B.BC.CD.Dddmmyy

hhmmss{

CR}AA.ABB.BC.CD

.Dddmmyyhhmmss{

CR}AA.ABB.BC.CD

.Dddmmyyhhmmss{

CR}AA.ABB.BC.CD

.Dddmmyyhhmmss

(see Description of

Arguments)

1:1 Operational

Mode

ASW=

1 byte, value of 0

or 1

Command or Query.

Sets or returns 1:1 operational mode in the form x, where

0 = Unit is in Manual Mode

1 = Unit is in Auto Mode

Note: In Manual Mode, all fault relays are forced to the non-faulted condition. This

allows the online unit to be configured without an unintended switchover to the

backup unit.

ASW=

ASW?

ASW*

ASW#

ASW?

ASW=x

(see Description of

Arguments)

Force 1:1 Switch FSW=

None

Command only.

This command takes no arguments.

Forces the unit to toggle the Unit Fail relay to the ‘fail’ state for approximately

500ms. If the unit is part of a 1:1 pair and it is currently the ‘On Line’ unit, this

forces a switchover, so the unit is then be in ‘Standby’ mode.

Notes:

1) The 1:1 redundancy system must be installed.

2) Both online and offline units must be in Manual Mode for this command to

function.

3) If the 1:1 redundancy system is not installed, or the unit is offline, then the

command returns FSW?

FSW= (message

OK)

N/A

N/A

Outdoor Unit

Comms Enable

ODU=

1 byte,

value of 0 or 1

Command or Query – CDM-570A Only.

Enables or disables communications, via the FSK link, with a Comtech EF Data

transceiver (ODU) in the form x, where:

0 = Disabled

1 = Enabled

Example: <0/ODU=0 (ODU disabled)

ODU=

ODU?

ODU*

ODU#

ODU?

ODU=x

(see Description of

Arguments)