9 bdlc module initialization, 1 initialization sequence, Bdlc module initialization -47 – Freescale Semiconductor MPC5200B User Manual

Page 726: Initialization sequence -47, Basic bdlc module transmit flowchart -47, Figure 20-19. basic bdlc module transmit flowchart, Bc c

Advertising
background image

Functional Description

MPC5200B Users Guide, Rev. 1

Freescale Semiconductor

20-47

Figure 20-19. Basic BDLC Module Transmit Flowchart

20.8.9

BDLC Module Initialization

This section includes sample flows for initializing the BDLC module and using it to transmit and receive messages.

20.8.9.1

Initialization Sequence

To initialize the BDLC module, the user should first write the desired data to the configuration bits. The BDLC module should then be taken
out of digital and analog loopback mode and enabled. Exiting from loopback mode will entail change of state indications in the BDLC State
Vector Register which must be dealt with. Once this is complete, CPU interrupts can be enabled (if desired), and then the BDLC module is
capable of SAE J1850 serial network communication. For an illustration of the sequence necessary for initializing the BDLC module, refer
to

Figure 20-20

.

Enter BDLC module Transmit

Routine

Write first message

byte to be transmitted

into DLCBDR

Is DLCBSVR = $00?

Yes

No

Load next byte to be

transmitted into DLCBDR

(clears TDRE)

Is DLCBSVR = $1C?

Yes

No

Is DLCBSVR = $14?

Yes

No

Is DLCBSVR = $10?

Yes

No

(TDRE)

(LOA)

(Invalid Symbol)

Attempt another

Yes

No

transmission?

Is this the last

Yes

No

byte?

A

A

Jump to BDLC module

Receive Routine

Once BDLC module detects

EOF, transmit

Set TEOD bit

in DLCBCR2

attempt is complete

Yes

No

IFR Received?

Jump to Receive IFR

Handling Routine

Exit BDLC module Transmit

Routine

B

B

C

C

Go to BDLC module

BREAK/Error Handling

Routine

For interrupt driven systems,
this marks the beginning of the
transmit section of the BDLC
module interrupt service
routine

NOTE: The EOF and CRC Error interrupts
are handled in the BDLC module Receive
Routine