Freescale Semiconductor MPC5200B User Manual

Page 760

Advertising
background image

MPC5200B Users Guide, Rev. 1

Freescale Semiconductor

B-9

19.5.16

MSCAN Transmit Error Counter Register (CANTXERR)-MBAR + 0x091D/0x099D.................... 19-17

19.5.17

MSCAN ID Acceptance Registers (CANIDAR0-7)—MBAR + 0x0920 / 0x09A0 .......................... 19-18

19.5.18

MSCAN ID Mask Register (CANIDMR0-7)—MBAR + 0x0928 / 0x09A8..................................... 19-20

Section

19.6.1

Identifier Registers (IDR0-3) ................................................................................................................... 19-24

19.6.2

Data Segment Registers (DSR0-7) ..................................................................................................... 19-24

19.6.3

Data Length Register (DLR) .............................................................................................................. 19-25

19.6.4

MSCAN Transmit Buffer Priority Register (TBPR)—MBAR + 0x0979 / 0x09F9........................... 19-25

19.6.5

MSCAN Time Stamp Register High (TSRH)—MBAR + 0x097C / 0x09FC.................................... 19-26

19.6.6

MSCAN Time Stamp Register Low (TSRL)—MBAR + 0x097D / 0x09FD .................................... 19-26

Section

20.7

Memory Map and Registers ....................................................................................................................... 20-5

20.7.3.1

BDLC Control Register 1 (DLCBCR1)—MBAR + 0x1300 ............................................................... 20-5

20.7.3.2

BDLC State Vector Register (DLCBSVR) - MBAR + 0x1300 ........................................................... 20-7

20.7.3.3

BDLC Control Register 2 (DLCBCR2) - MBAR + 0x1304 ................................................................ 20-8

20.7.3.4

BDLC Data Register (DLCBDR) - MBAR + 0x1305........................................................................ 20-12

20.7.3.5

BDLC Analog Round Trip Delay Register (DLCBARD) - MBAR + 0x1308 .................................. 20-12

20.7.3.6

BDLC Rate Select Register (DLCBRSR) - MBAR + 0x1309 ........................................................... 20-14

20.7.3.7

BDLC Control Register (DLCSCR) - MBAR + 0x130C................................................................... 20-15

20.7.3.8

BDLC Status Register (DLCBSTAT) - MBAR + 0x130D................................................................. 20-15

Section

21.8.1.1 Device ID Register ..................................................................................................................................... 21-8

Advertising