Other function outline, Tie-line connection, Pbx interface (e and m interface) – Toa N-8000 Series User Manual

Page 104

Advertising
background image

1-87

Chapter 1

GENERAL DESCRIPTION

11. OTHER FuNCTION OuTLINE

11.1. Tie-line Connection

Conversations or paging can be performed by connecting the N-8000MI unit to the exchange of EXES-2000 or

EXES-6000 Series intercom systems. Wiring requires two pairs of cables per line, and the connected exchange

must be equipped with a Tie-line unit (TI-20A for the EXES-2000 and TI-600 for the EXES-6000).

N-8000MI

Audio signal: 2 pairs

(0 dB)*

TI-20A

TI-600

EXES-2000

EXES-6000

* 0 dB = 1 V

11.2. PBX Interface (E and M Interface)

Connecting the N-8000MI unit to a PBX permits conversations to be made between the intercom station and

the telephone, or paging calls to be initiated from the telephone. The N-8000MI is connected to a standard

PBX analog E&M interface using 3 pairs of cables per line. Since the ground return method is employed for

the installation of the system connecting between the trunk and the N-8000MI, use grounding or connect the

grounding cable separately.

N-8000MI

Audio signal: 2 pairs (0 dB*)

Control: 1 pair (E and M)

PBX

analog E&M interface

Grounding

or

Direct connection

Grounding

Advertising