Toa N-8000 Series User Manual

Page 162

Advertising
background image

2-51

Chapter 2

FUNCTIONS AND OPERATION

MASTER STATION'S FUNCTIONS AND OPERATION

[External timer-initiated event settings]

• "Time Signal" broadcasts can be triggered by make contact from an external timer connected to the N-8000AF

Audio Interface's contact input.

• The external timer-initiated event is comprised of the following contents for each contact input (1 − 8): Paging

zones (up to 10 zones selected from 192), sound source numbers (0 − 9) and external equipment control (ON

or OFF).

5.3.2. Automatic time signal activation

[Operation]

• Audible time signal can be broadcast in synchronization with preprogrammed events.

• Schedules to be activated must be set in advance.

Time signal is broadcast over preset paging zones when the event activation time for each preset schedule

is reached.

• Only one (1) N-8000AF in the system can be set to transmit the time signal.

• The time signal sound source can be either the N-8000AF's internal sound source or an external sound

source connected to the N-8000AF.

• Contact output terminals (any of contact outputs 5 − 8, including those of another N-8000AF, N-8000MI, or

N-8000DI) can be closed to operate a bell or other external equipment in synchronization with Time Signal

Activation.

• New events activated during Time Signal operation are ignored.

• Time Signal operation is terminated when the preset sound source operation time elapses.

• The function to limit the paging time does not operate.

• If "Silent" is selected and external equipment control is set to OFF, nothing is operated.

[Activation]

The following two methods can be used to automatically trigger the time signal.

(1) Activation by Internal Timer

• Time signal begins operation in synchronization with the preprogrammed event activation schedule.

• Time is managed by the N-8000AF's internal timer.

• Schedules to be activated can be changed through operation of any master station.

(2) Activation by External Timer

• The Time Signal begins operation when the N-8000AF receives make contact from the connected external

timer.

• Connect the external timer to the N-8000AF's contact inputs (1 − 8).

• The Time Signal operates according to the external timer-initiated events preprogrammed for the individual

contact inputs.

• The Time Signal is activated by make contact from the external timer. However, opening the contact will not

terminate Time Signal operation.

[Conceptual diagram]

Contact inputs 1 – 8

Audio input

Contact outputs 1 – 4

Timer

External sound source